双通道数字合成信号源 HP 3326A /opt001,opt002,opt003 性能指标pdf
The HP 3326A Two-Channel Synthesizer combines two independent synthesizers, flexible modulation, and control circuitry into a single, powerful package.  This single instrument can provide precise phase offset, two-tone sweep, fast frequency switching, internal modulation, and pulse signals for bench or systems use.
Complete Two-Phase Modulation
The HP 3326A can provide two signals whose phase is adjustable and calibrated anywhere in its 13 MHz frequency range without an external phasemeter.
Self-calibration can be performed internally or externally and yields accuracy of ± 0.2 degrees below 100 kHz.  Phase can be set with 0.01 degree resolution at all frequencies.  Using its unique phase-calibration circuitry, calibrated multi-phase signals are easily achieved with two or more HP 3226As.
Powerful Two-Tone Capability
The HP 3326A is the single-source answer for producing a wide variety of broadband two-tone signals.  Its two channels can be offset up to ± 100 kHz, either in the CW mode or while sweeping.
Channel amplitudes and functions (sine or square) can be selected independently and provided from separate outputs or through the built-in signal combiner.  Low sinewave distortion (harmonics are at least -70 dBc below 100 kHz) makes low-distortion intermodulation measurements a simple task.
Versatile ATE Source
With two complete synthesizers in a single instrument, rack space and power are conserved.  Features like internal amplitude and phase modulation, two-tone, and pulse modes allow this one instrument to do the job of several sources.
All functions, modes, and parameters of the HP 3326A are completely programmable over the HP-IB.  Maximum accuracy is ensured with amplitude/phase calibrations that can be enabled, disabled and initiated under remote control.
High Performance Modulation and Pulses
Precise amplitude and phase modulation is easy with both channels of the HP 3326A.  Each channel can be used with simultaneous AM and PM, or one channel can modulate the other.  Amplitude modulation frequency is dc to 100 kHz and envelope distortion is better than -46 dB.
In the pulse mode both pulse and pulse-complement outputs are provided.  Symmetry range is 1% to 99% and is settable in 0.1% increments.  In addition, both pulse amplitudes and their offsets are independently controllable.
Other Features
The HP 3326A has a host of convenience features to speed and simplify signal generation.  Nine complete setup states can be stored in nonvolatile memory, along with automatic storage of the power-off state.  A discrete sweep mode is available to generate from 2 to 63 frequency pairs with dwell times individually selectable for each frequency and each channel.  Several flexible triggering modes allow hardware or software triggers to initiate frequency, amplitude, or phase changes, and sweeps.
DC offset is available in all modes, and all outputs are floating.  Frequency resolution is 11 digits, and all sweeps and frequency changes are phase-continuous.
Two Channel Synthesizer, DC to 13 MHz 
Combines two independent synthesizers, flexible modulation and control circuitry into a single, powerful package  Provides precise phase offset, two-tone sweep, fast frequency switching, internal modulation, and pulse signals  Internal switch selected signal combiner sums both source outputs into a single ultra-low IMD signal source  Phase continuous sweeps are available in linear and multielement discrete modes  DC offset is available in all modes, and all outputs are floating  Specification Summary 
Frequency (waveforms are sine, square, pulse, and dc) * Range: 0 Hz to 13 MHz * Resolution: 1 µHz below 100 kHz, 1 mHz at and above 100 kHz * Output Amplitude (sine mode) - Range: 1 mVpp to 10 Vpp in 8 ranges without DC offset  Phase Offset (channel A vs B in two-phase mode) * Range/Resolution: = 720 degrees range, 0.01 degree resolution  Frequency Sweep * Sweep Types: linear, discrete (2-63 discrete elements) * Sweep Time: 5 ms to 1000 s, Linear or per element  Modes 
Two-Channel: Channels A and B are independent  Two-Phase: Channels A and B are the same frequency, with a calibrated phase difference between them  Two-Tone: Channel B frequency must be within 100 kHz of the Channel A frequency  Pulse: Channel B is the complement of the Channel A output  Amplitude Modulation Channel A and Channel B outputs with external modulation or to the Channel A output with internal modulation (Channel B is the modulation source). 
Waveforms: Sine, square, or pulse (pulse allowed in external only)  Carrier Frequency Range: DC to 13 MHz  Modulation Frequency Range: DC to 100 kHz  Modulation Depth: 0 to 100%  Phase Modulation Channel A and Channel B outputs with external and synchronous phase modulation, and to the Channel A output with internal phase modulation (Channel B is the modulation source). 
Waveforms: Sine, square or pulse (pulse allowed in external only)  Carrier Frequency Range: DC to 13 MHz  Phase Deviation: ±360°  Auxiliary Outputs 
Sync A  X-axis Drive  Z-axis Blank  Sweep Marker  10 MHz Reference  Auxiliary Inputs 
External Reference Input  External Trigger  Channel A External Phase Calibration  Channel B External Phase Calibration  Channel A External Amplitude Modulation  Channel B External Amplitude Modulation  Channel A External Phase Modulation/Synchronous Phase Modulation  Channel B External Phase Modulation  Save/Recall Memory
电话: 010 - 62123258    邮箱: buy17@163.com
|